To allow easier analysis of the oil pump status fields output in
CSV. Also change the update to have no delay between requesting
each status value but maintain 100ms between each group of
requests.
Lots of fields had the same value after an overnight cold soak with a 40 degree offset from the drive-unit case temp. Running the pump causes some temps to increase but other stay the same.
Supply voltage and current tested with a bench power
supply. Values track measured values quite accurately.
This Arduino sketch connects to the oil pump over LIN using the
hardware serial on an ESP32. According to the captures taken of
the LIN of a running inverter there is 1 outgoing command and
4 status requests. The outgoing command appears to be the
desired speed of the pump. The incoming status messages are
currently not understood so are just printed out as hex values.
The speed can be changed by supplying a numeric value between
0 and 255 followed by CR/LF.