Run the oil pump for about a minute at full speed and
capture the log in short-run.ods. This allows various
status parameters to be graphed against time.
It looks like 30_Byte3 ramps up first and the graph
follows the pitch which can be heard from the motor.
Label this as Motor_Speed.
The 2A_Byte1 values ramp up next and this reflects the
observed behaviour when emptying the old oil out of
my drive unit where there was a perceptible delay
between the motor spinning up and the fluid flow. This
value ramps down with a lag after the Speed_Request
returns to 0.
The 2A_Byte2 value looks like the best guess for the
pump pressure. It peaks a bit after the flow and RPM
have stabilised and tails away steadily. This would
likely be expected in my drive unit which only has a
small amount of oil it it currently. No idea if the value is
from a sensor or some sort of clever fusion from the 3-
phase motor controller.
The change contains captures of the LIN interface connecting
the main M3 inverter to the oil pump. They were captured
with Saleae Logic 2.3.37 from power on of the inverter. The power supply was low (circa 11V) and the pump appeared stalled.
Startup_Oil_Pump_Disconnected - No oil pump connected
Startup_Oil_Pump_Connected - Normal operation from cold
Startup_Oil_Pump_Hairdrier-1 - Warm the oil pump casing
for about 30 seconds with a hair drier.
Startup_Oil_Pump_Hairdrier-2 - Warm the oil pump casing for 2-3 minutes with a hair drier.